Skip to content

Electrical Troubleshooting in Palm Beach County

K&J Electrical Solutions traces flickering lights, tripping breakers and dead outlets to the real cause and fixes it, for homes across Palm Beach County. The electrician tests the circuit instead of guessing and explains what was found before repair work starts. Family-owned and owner-operated, phone answered 24/7 at (561) 777-9982.

License EC13016308 Answered 24/7

What's Included

Every electrical troubleshooting job covers these 7 points, done by Jake or Kevin themselves.

  • Testing the circuit, its connections and its devices to find the actual cause
  • Flickering and dimming lights, from bulbs and dimmers to loose connections and panel or service causes
  • Tripping breakers, whether the cause is an overload, a short, a ground fault or a worn breaker
  • Dead outlets and switches, from a tripped GFCI to a loose or burned connection
  • Repair or replacement of the faulty breaker, outlet, switch, fixture or wire section
  • A plain explanation of what was found, and your options, before repair work begins
  • Affected circuits tested again after the repair

Signs You Need It

If you notice any of these, it is time to call about electrical troubleshooting.

  • Lights flicker, dim or buzz, in one room or across the house
  • A breaker trips again right after you reset it, or trips with nothing running
  • An outlet or switch has stopped working
  • A GFCI outlet will not reset
  • Lights dim when the air conditioner or another large appliance starts
  • Only some of the outlets in a room work

Ready to talk about electrical troubleshooting? You'll deal with Jake or Kevin directly.

What is electrical troubleshooting?

Electrical troubleshooting is finding the actual cause of a fault and fixing that cause, instead of replacing parts until the symptom goes away. For most homeowners it starts with one of three things: lights that flicker or dim, a breaker that keeps tripping, or an outlet that has stopped working.

The method is the same every time. The electrician tests the circuit, its connections and the devices on it, narrows the problem to one spot, and explains what was found before any repair begins. If it is urgent, the 24/7 emergency electrician page covers what to do right now.

Why do my lights flicker or dim?

Flickering has a short list of causes. The simple ones are a worn or loose bulb, a dimmer that does not suit the bulbs on it (common with LED bulbs), or a switch that is wearing out. The more serious ones are a loose connection in a fixture, a junction box or the panel, an overloaded circuit, or a problem with the service coming into the home.

Where and when it happens tells you a lot. One fixture usually points to that bulb, switch or fixture. Lights that dim when the air conditioner or another large appliance starts point to the load on the circuit or the service. Flickering in several rooms, or flickering with a buzz or a burning smell, is worth a call right away, because a loose connection can heat up. The Electrical Safety Foundation International lists flickering and dimming lights among the warning signs of an overloaded circuit or a wiring problem.

Why does my breaker keep tripping?

A breaker trips to stop a fault, so a trip is information, not just a nuisance. There are three common reasons, plus a worn breaker:

  • Overload. Too much is running on one circuit. A 15-amp, 120-volt circuit carries about 1,800 watts at most (15 amps times 120 volts), or about 1,440 for loads that run three hours or more. A 20-amp circuit carries about 2,400 watts at most, or about 1,920 for loads that run three hours or more. A space heater and a hair dryer on the same circuit can pass the limit.
  • Short circuit. A hot wire touches a neutral or another hot wire. The breaker trips at once, often with a pop.
  • Ground fault. Current leaks to ground, often through a damaged wire or a wet appliance or fixture.
  • A worn breaker. Breakers wear out and can trip below their rating.

The size of the breaker is matched to the wire behind it. Under the National Electrical Code, standard copper house wiring is limited to a 15-amp breaker for 14-gauge wire, 20 amps for 12-gauge and 30 amps for 10-gauge (Section 240.4(D)). That is why a bigger breaker is never the fix: it lets the wire carry more current than it can take. If a breaker trips again right after you reset it, or trips with nothing running, leave it off and call.

Why is my outlet or switch dead?

Before assuming the outlet itself is bad, look at what else is on the circuit. The usual causes are:

  • A tripped breaker.
  • A tripped GFCI outlet somewhere else on the circuit. One GFCI outlet in a bathroom, kitchen, garage or outdoors can protect other outlets downstream.
  • A loose or burned connection behind the wall or in the device.
  • A failed outlet or switch.
  • An outlet that a wall switch controls, which is common in living rooms and bedrooms.

The U.S. Consumer Product Safety Commission recommends testing every GFCI once a month: plug in a light, press the test button and the light should go out, then press reset and it should come back on. If it does not, the GFCI needs to be replaced. The same checklist warns that unusually warm outlets or switches may mean an unsafe wiring condition, such as a loose connection that can start a fire. Some dimmers warm up normally. A warm or discolored outlet is one to stop using until an electrician looks at it. When the outlet or switch itself is the problem, or you want a GFCI, a tamper-resistant outlet or a new switch while the box is open, see outlets and switches.

When is it an emergency instead?

A burning smell, sparking, a hot or buzzing panel, scorch marks or a shock is urgent, not something to schedule for next week. Turn off the affected circuit if you can do it safely, keep people away from the area and call (561) 777-9982, which is answered 24/7. If there is smoke or fire, call 911 first.

Less dramatic signs still count. Breakers that trip repeatedly, lights that dim when the AC starts and outlets that work only sometimes point to a fault that tends to get worse, not better. If the same fault keeps coming back in an older home, an inspection and rewiring visit may be the better fix.

What can I safely check myself?

Some checks are safe for anyone, and they make the visit faster:

  1. Note what happens, where it happens and when it started or last worked.
  2. Unplug what is on the affected circuit, then reset the breaker once. Do not keep resetting it.
  3. Press reset on any GFCI outlets nearby, and swap in a new bulb or try a different switch.
  4. Check whether a wall switch controls the outlet.

Leave the panel cover and the wiring to an electrician. The wires coming in from the utility stay energized even with the main breaker off. If a panel upgrade turns out to be the real answer, the troubleshooting visit will show it, and surge protection is worth a look if storms keep taking out equipment.

Who does electrical troubleshooting in Palm Beach County?

K&J Electrical Solutions does. We are a family-owned, owner-operated electrician in Palm Beach County, run by Jake and Kevin, and the two of them do the work themselves. You describe the problem, we test the circuit, and you hear what we found before any repair starts. We work across the county, including West Palm Beach, Boynton Beach, Delray Beach, Boca Raton, Lake Worth Beach and Wellington. Our phone is answered 24/7 at (561) 777-9982, and it takes texts too, or you can request an estimate.

Sources

  • National Fire Protection Association, NFPA 70, National Electrical Code (overcurrent protection of conductors, Section 240.4(D); branch-circuit loading, Sections 210.19 and 210.20; arc-fault protection, Section 210.12): nfpa.org
  • EC&M, The Apprentice’s Guide to AFCIs and the NEC, January 31, 2025: ecmweb.com
  • U.S. Consumer Product Safety Commission, Home Electrical Safety Checklist, Pub 513, July 2008: cpsc.gov
  • Electrical Safety Foundation International, Don’t Overload Your Home (warning signs of an overloaded circuit): esfi.org
  • Electrical Safety Foundation International, Indoor Electrical Safety Check booklet (what an outlet GFCI protects, monthly testing): esfi.org

Electrical Troubleshooting Questions

Why do the lights flicker in just one room?

One room usually points to something on that circuit, such as a worn bulb, a dimmer that does not suit the bulbs, a failing switch or a loose connection in the fixture or its box. If only that fixture flickers, start with the bulb and the switch. If it keeps happening, K&J Electrical Solutions can test the circuit and find the cause.

Why does my breaker trip when I run the microwave and the toaster together?

Most likely the circuit is overloaded. A 15-amp, 120-volt circuit is good for about 1,800 watts at most (about 1,440 for loads that run three hours or more) and a 20-amp circuit for about 2,400 at most (about 1,920 for loads that run three hours or more), and two heating appliances can pass that together. If it trips with nothing running, or right after a reset, leave it off and call (561) 777-9982.

Can I put in a bigger breaker to stop the tripping?

No. The breaker protects the wire. Under the National Electrical Code, standard copper house wiring is limited to a 15-amp breaker for 14-gauge wire and 20 amps for 12-gauge (Section 240.4(D)), so a bigger breaker lets the wire carry more current than it can handle. K&J Electrical Solutions finds out why it trips instead.

What should I check when an outlet is dead?

Check the breaker, then look for a GFCI outlet in the bathroom, kitchen, garage or outdoors, because one GFCI can protect other outlets on the same circuit. Press its reset button. Also check whether a wall switch controls the outlet. If it still has no power, or feels warm or looks discolored, stop using it and call.

Why does my GFCI or arc-fault breaker keep tripping?

A GFCI trips when current leaks to ground, often from a wet or damaged appliance, cord or outdoor fixture. An arc-fault (AFCI) breaker trips when it detects arcing, such as from a loose or damaged wire. Either one can also be worn out. K&J Electrical Solutions tests the circuit to tell which it is.

How does an electrician find the cause of a tripping breaker?

By testing instead of guessing. The electrician checks the breaker and the circuit, disconnects loads one at a time, and tests the wiring and devices on that circuit until the fault is isolated to one spot. K&J Electrical Solutions then explains what was found and what it takes to fix it.

Still have a question? Ask the owners directly.

Need help right now?

Call or text (561) 777-9982. We answer 24/7, and you get Jake or Kevin, not a call center.

Power out, burning smell, sparking outlet or a breaker that won't reset? Call now.

Not urgent? Request a free estimate.

We typically reply within one business hour.

* Required. We only use your details to answer your request.

Other ways to reach us

K&J Electrical Solutions logo

K&J Electrical SolutionsBoynton Beach, FL

Open our Facebook page Recommend us on Nextdoor
Address
K&J Electrical Solutions
9377 Longmeadow Cir, Boynton Beach, FL 33436
Service area
Palm Beach County, FL
License
Licensed and insured Florida electrical contractor EC13016308
K&J Electrical Solutions logo

We Answer 24/7

Need an electrician? Jake or Kevin picks up, day or night.

Emergency service
24/7, every day
Service area
Palm Beach County
FL license
EC13016308
Call (561) 777-9982