Skip to content

Outlet and Switch Installation and Repair in Palm Beach County

K&J Electrical Solutions replaces, adds, moves and repairs outlets and switches in homes across Palm Beach County, from GFCI and USB outlets to dimmers, 3-way and smart switches. Every device is matched to the circuit and the box behind it, and to what the electrical code asks for in that spot. Family-owned and owner-operated, phone answered 24/7 at (561) 777-9982.

License EC13016308 Answered 24/7

What's Included

Every outlets and switches job covers these 7 points, done by Jake or Kevin themselves.

  • Worn, loose, cracked or discolored outlets and switches replaced
  • New outlets added where you need them, and existing ones moved
  • GFCI outlets or GFCI breakers where the code calls for that protection
  • Tamper-resistant outlets indoors, and weather-resistant outlets with the right cover outside
  • USB, 20-amp and dedicated-circuit outlets for appliances, a TV wall or a work area
  • Dimmers, 3-way and 4-way switches, and smart switches in boxes that have the wires they need
  • Every new device tested once it is in, and every GFCI tripped and reset

Signs You Need It

If you notice any of these, it is time to call about outlets and switches.

  • An outlet feels warm, buzzes, smells burnt or has dark marks around the slots
  • Plugs slip out of an outlet or hang loose in it
  • The house still has two-prong outlets
  • A bathroom, the kitchen counter, the garage or an outside wall has no GFCI protection
  • Extension cords and power strips stay plugged in because a room is short on outlets
  • A light can be switched from only one end of a hallway or staircase
  • An outdoor outlet cover is broken or cannot close with a cord plugged in

Ready to talk about outlets and switches? You'll deal with Jake or Kevin directly.

Can you replace, add or move an outlet?

Yes to all three. An outlet gets replaced when it is worn out, cracked or discolored, when plugs no longer stay in it, or when it is the wrong type for where it sits. The U.S. Consumer Product Safety Commission’s home checklist says an outlet that no longer holds a plug snugly should be replaced, because a loose fit can overheat.

Adding an outlet means extending a circuit that has capacity to spare, or running a new circuit from the panel. Moving one, for a new furniture layout or a wall-mounted TV, means running cable to the new spot and either taking the old box out of the circuit or leaving it as a junction box under a blank cover. The same checklist says extension cords are not as safe as permanent house wiring, and that new outlets belong where cords have become permanent.

A replacement outlet also has to meet the rules for its spot today, not the rules from the year the house was built. Where the code now calls for GFCI or arc-fault protection, a tamper-resistant outlet or a weather-resistant one, the replacement has to provide it (Section 406.4(D)). K&J confirms whether the job needs a permit and pulls it when it does.

Is my outlet dead, or is a GFCI tripped somewhere else?

Check for a tripped GFCI before blaming the outlet. A single GFCI can sit ahead of several ordinary outlets on the same circuit, sometimes in another room, and when it trips, every outlet after it loses power too. Nothing on the dead outlet itself shows why.

Press the reset button on each GFCI you can find, then look at the breaker panel. If power does not come back, the electrical troubleshooting page covers the other causes and how K&J tests the circuit to find the one you have.

What can replace a two-prong outlet?

When the box has no equipment ground, the code allows three replacements, and a plain three-prong outlet is not one of them (Section 406.4(D)(2)). Where a ground is present, the replacement has to be a grounding-type outlet connected to it (Section 406.4(D)(1)), so K&J tests the box before choosing:

  • Another two-prong outlet. It works as before, with no ground slot.
  • A GFCI outlet. It gets a “No Equipment Ground” label and adds shock protection at that outlet even without a ground wire.
  • A three-prong outlet fed through a GFCI, either a GFCI outlet upstream or a GFCI breaker in the panel. It gets labeled “GFCI Protected” and “No Equipment Ground”.

A GFCI does not give the outlet a ground. Some appliance makers require a ground wire in the circuit, and the code’s list of plug-in equipment that needs one includes refrigerators, freezers and air conditioners (Section 250.114). For those, the real fix is new wiring that brings a ground to the box, which is often part of rewiring an older home.

Where does a home need GFCI outlets?

Section 210.8 of the National Electrical Code lists the places: bathrooms, garages, outdoors, crawl spaces, basements, kitchen countertops, within 6 feet of a sink, laundry areas, near a tub or shower outside a bathroom, boathouses, and indoor damp or wet locations. The rule covers 125-volt through 250-volt outlets in those spots, whatever their amp rating.

The protection can come from a GFCI outlet at that spot, a GFCI outlet upstream on the same circuit, or a GFCI breaker in the panel. The list has grown over the code’s editions, so an older Palm Beach County home can be missing protection a new one would have. The CPSC asks homeowners to test every GFCI once a month. One that does not cut the power when you press TEST needs replacing. One that will not come back on with RESET is not always the problem: it may have no power coming in, a wiring fault or a fault further down the circuit, so leave those outlets unused and have the circuit checked. Outlets close to a pool follow the pool rules as well, covered under pool electrical.

What are tamper-resistant outlets, and where are they required?

Tamper-resistant outlets have spring-loaded shutters behind the slots that open only when both prongs of a plug push in together, so a key or a hairpin pushed into one slot meets plastic instead of metal. The National Electrical Code first required them in new and renovated homes in its 2008 edition.

Today the code calls for them on standard 15- and 20-amp, 125- and 250-volt outlets in a home, including attached and detached garages and accessory buildings (Section 406.12). The exceptions are narrow: outlets more than five and a half feet above the floor, outlets built into a light fixture or an appliance, a single outlet (or a duplex serving two appliances) in the dedicated space for a cord-connected appliance that is not easily moved, and a two-prong outlet put in as a like-for-like replacement. When an outlet in one of the covered spots is replaced, the new one has to be tamper-resistant as well.

Which outlets hold up outdoors in salt air?

Weather-resistant outlets under a cover rated for the spot. Outside, outlets in Palm Beach County face sun, summer storms, sprinklers and, close to the ocean, salt air, and the code requires 15- and 20-amp outlets in damp and wet locations to be the listed weather-resistant type (Section 406.9). Those devices use corrosion-resistant metal parts and plastic made to resist the sun’s UV.

The cover depends on where the outlet sits:

  • Under a roofed porch or lanai that rain and runoff do not reach, which generally counts as a damp location, the cover has to keep water out when nothing is plugged in.
  • Out in the open, a wet location, the enclosure has to stay weatherproof with a cord plugged in, which means an in-use cover listed as extra-duty. Where wind-driven rain, a sprinkler or runoff can reach an outlet under a roof, K&J uses the same in-use cover.

The CPSC points out that most ordinary covers do not keep water out while a cord is plugged in, because water runs down between the plug and the outlet. Outdoor outlets at a home need GFCI protection too.

Can you install USB, 20-amp and dedicated-circuit outlets?

Yes, and each one starts with the circuit behind it.

  • USB outlets replace a standard outlet and add charging ports. K&J checks that the box has room for the device and its wires before one goes in.
  • 20-amp outlets belong on 20-amp circuits. On an ordinary household circuit that feeds more than one outlet, a 15-amp circuit takes 15-amp outlets and a 20-amp circuit takes 15- or 20-amp ones (Sections 406.4(A) and 210.21(B)), and every outlet is marked with its amp rating. Swapping in a 20-amp outlet does not add capacity: the wire and the breaker decide that.
  • Dedicated circuits feed one appliance or one outlet. When a new appliance’s instructions call for a circuit of its own, K&J runs one from the panel, and a single outlet alone on a circuit has to be rated at least as high as the circuit (Section 210.21(B)). If the panel has no room left, panel upgrades covers the options.

For a TV wall, an outlet placed behind where the screen will hang keeps the power cord out of sight.

Which switch do I need: a dimmer, a 3-way or a smart switch?

It depends on what the switch runs and from how many places.

  • Dimmers have to suit the bulbs they control. ENERGY STAR notes that not every LED light works well with every dimmer, and the lighting page covers matching dimmers to LED lights and fan controls to fans.
  • 3-way switches come in pairs and control one light from two places, such as the top and bottom of a staircase or both ends of a hall. A 4-way switch between them adds a third place. Turning a single switch into a pair usually means running new cable between the two switch locations.
  • Smart switches often need a neutral wire in the box, and not every switch box has one. The home automation page explains what to check before you buy one.

A switch that is not working properly deserves a look. The CPSC notes that a worn switch, or a loose screw holding a wire, can lead to arcing, overheating or a fire.

What if an outlet is warm, buzzing or scorched?

Stop using it, unplug what is in it if you can do so safely, and call (561) 777-9982. A buzz, a burnt smell, a cover plate that feels hot, or brown or black marks around the slots point to heat or arcing inside the box, often from a loose or failing connection. If you can reach the panel safely, switch that circuit’s breaker off.

This is the one outlet job that should not wait for a convenient day. Call 911 first if you see smoke or fire. The 24/7 emergency electrician page covers what to do while you wait.

Who installs outlets and switches in Palm Beach County?

K&J Electrical Solutions does. The company is family-owned and run by Jake and Kevin, who do the work themselves, so you deal with one of the owners from the first call to the final test. Tell us how many outlets or switches you need and where, and we will check the circuits behind them before anything changes. We work across the county, including Boynton Beach and the Aberdeen area west of it, Delray Beach, West Palm Beach, Lake Worth Beach, Boca Raton and Jupiter. Call or text (561) 777-9982, answered 24/7, or request an estimate.

Sources

  • National Fire Protection Association, NFPA 70, National Electrical Code (receptacles, Article 406; GFCI protection, Section 210.8; receptacle ratings, Section 210.21(B)): nfpa.org
  • EC&M, Mike Holt, NEC Requirements for Receptacles, June 10, 2026 (replacement rules, Section 406.4(D); tamper-resistant scope and exceptions, Section 406.12; damp and wet locations, Section 406.9): ecmweb.com
  • EC&M, Russ LeBlanc, Non-Grounding Receptacle Replacement, February 14, 2017 (GFCI replacement marked “No Equipment Ground”, Section 406.4(D)(2)): ecmweb.com
  • EC&M, Harold De Loach, The Apprentice’s Guide to Art. 406, September 14, 2023 (ratings matched to the circuit, Sections 406.4(A) and 210.21(B); equipment that needs a ground, Section 250.114): ecmweb.com
  • EC&M, Mike Holt, Stumped by the Code? Requirements for GFCI Protection of Branch Circuit Receptacles in Dwelling Units, March 11, 2021 (dwelling GFCI locations, Section 210.8(A)): ecmweb.com
  • EC&M, Mike Holt, Code Q&A: Placing Receptacles in Damp or Wet Locations, October 21, 2015 (roofed open porches as damp locations; covers for damp and wet locations): ecmweb.com
  • EC&M, Joseph Wages Jr., Receptacle Deterioration Issues in Wet or Damp Locations, April 29, 2021 (what makes a receptacle weather-resistant): ecmweb.com
  • IAEI Magazine, Thomas A. Domitrovich, Tamper-Resistant Receptacles, November/December 2013 (how the shutters work; first required in homes in the 2008 NEC): iaeimagazine.org
  • IAEI Magazine, NEMA, Check and Be Sure of GFCI Safety Protection, January/February 2000 (downstream outlets lose power when a GFCI trips; a GFCI that fails its test must be replaced): iaeimagazine.org
  • Leviton, Captain Code: 2020 NEC Code Changes (NEC text reprinted with permission from NFPA 70, 2020 edition; tamper-resistant exceptions, Section 406.12): leviton.com
  • U.S. Consumer Product Safety Commission, Home Electrical Safety Checklist, Pub 513, July 2008 (loose-fitting plugs, warm outlets and switches, worn switches, monthly GFCI tests, outdoor covers, extension cords): cpsc.gov
  • ENERGY STAR, Light Fixtures (LED and dimmer compatibility): energystar.gov

Outlets & Switches Questions

Can a two-prong outlet be swapped for a three-prong one?

Only in certain ways when the box has no equipment ground. The electrical code allows another two-prong outlet, a GFCI outlet labeled "No Equipment Ground", or a three-prong outlet protected by a GFCI and labeled to say so (Section 406.4(D)(2)). A plain three-prong outlet with nothing behind its ground slot is not one of the choices. Where the box does have a ground, the new outlet has to be a grounding type connected to it (Section 406.4(D)(1)), so K&J Electrical Solutions tests the box first.

Why did several outlets stop working at once?

Often a GFCI outlet upstream on the same circuit has tripped, and everything after it lost power with it. Look for a GFCI in a bathroom, the kitchen, the garage or outside, press its reset button, and check the breaker panel. If the outlets stay dead, call (561) 777-9982 and K&J will trace the circuit.

Do new outlets in a home have to be tamper-resistant?

Yes, for standard 15- and 20-amp outlets in a home, with a few exceptions, such as outlets more than five and a half feet above the floor (Section 406.12). They have shutters that open only when both prongs of a plug push in at the same time. Replacements in those spots have to be tamper-resistant too.

What kind of outlet belongs outside?

A weather-resistant outlet with GFCI protection. Under a roofed porch or lanai that rain and runoff do not reach, its cover has to keep water out when nothing is plugged in. In the open, or anywhere wind-driven rain, a sprinkler or runoff can reach it, K&J uses an extra-duty in-use cover that stays weatherproof with a cord plugged in (Section 406.9).

Can you add USB outlets to my house?

Yes. A USB charging outlet replaces a standard one and adds charging ports. The box behind it has to have room for the device and its wires, so K&J Electrical Solutions checks each box before installing one.

Is a warm outlet dangerous?

It can be. The U.S. Consumer Product Safety Commission treats an unusually warm outlet or switch as a possible sign of unsafe wiring, for example a loose connection, which can start a fire. Its advice is to stop using it until an electrician has checked it, though a dimmer that runs slightly warm can be normal. Call (561) 777-9982, answered 24/7.

Still have a question? Ask the owners directly.

Need help right now?

Call or text (561) 777-9982. We answer 24/7, and you get Jake or Kevin, not a call center.

Power out, burning smell, sparking outlet or a breaker that won't reset? Call now.

Not urgent? Request a free estimate.

We typically reply within one business hour.

* Required. We only use your details to answer your request.

Other ways to reach us

K&J Electrical Solutions logo

K&J Electrical SolutionsBoynton Beach, FL

Open our Facebook page Recommend us on Nextdoor
Address
K&J Electrical Solutions
9377 Longmeadow Cir, Boynton Beach, FL 33436
Service area
Palm Beach County, FL
License
Licensed and insured Florida electrical contractor EC13016308
K&J Electrical Solutions logo

We Answer 24/7

Need an electrician? Jake or Kevin picks up, day or night.

Emergency service
24/7, every day
Service area
Palm Beach County
FL license
EC13016308
Call (561) 777-9982